Lead Acid Battery Maintenance Checklist


As per the epidemic of COVID-19, many places are locked down or carrying out quarantine policy, which would cause the consumption ability going down and the longer the storage time of the cargoes/goods. Considering the charateristics of lead acid batteries,here is the lead acid battery maintenance checklist.

·Recomended temperature for  lead acid battery maintenance:

·Warehouse management principle: First in First Out.

·Testing and inspecting of the sealed MF batteries’voltage every 3 months .

·If not recharged, the batteries may not be working due to high internal resistance.

· Do not turn the battery upside downin case acid leakage from the safety valve.





3.2.3.Recharge:

recharge voltage 14.4V-14.8V, recharge currency 0.1C, constant voltage charging time: 10-15 hours.

4.If not recharged, the batteries may not be working due to high internal resistance.

Recharge 30 mins of the dry charged batteries if it is stocked in warehouse more than one year; or the battery internal plates are oxidated in winter season with low temperature environment (recharge voltage 14.4V-14.8V, recharge currency 0.1C). 

5. Do not turn the battery upside downin case acid leakage from the safety valve.

If leakage happening, please take the leaking batteries from the others and clean it; in case the acid causes batteries short circuit. After cleaning the leaking batteries, please recharge the batteries as above steps.

Songli Battery is a global lead-acid battery technology expert. In addition, we have become one of the world’s most successful independent battery manufacturers.We sincererly thank you for your always trust on our battery products and service, and we are also improving ourselves and products to provide you more excellent products and service.